R422103315 2x2/2-way valve Series AV05 R422103315
AV05-2/2CC-VT00-024VDC-LOC
electric Double-acting Base plate principle multiple - NC/NC - - Notched 40 µm 60 °C 8 bar 60 °C - 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With spring return 580 l/min soft sealing 2x2/2 Plate connection Slide valve, without overlap -10% / +10% R422103316 2x2/2-way valve Series AV05 R422103316
AV05-2/2CC-VT00-024VDC-NLC
electric Double-acting Base plate principle multiple - NC/NC - - Notched 40 µm 60 °C 8 bar 60 °C - 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With spring return 580 l/min soft sealing 2x2/2 Plate connection Slide valve, without overlap -10% / +10% R422103317 2x2/2-way valve Series AV05 R422103317
AV05-2/2CC-VT00-024VDC-NO
electric Double-acting Base plate principle multiple - NC/NC - - Notched 40 µm 60 °C 8 bar 60 °C - 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With spring return 580 l/min soft sealing 2x2/2 Plate connection Slide valve, without overlap -10% / +10% R422103006 2x3/2-way valve Series AV05 R422103006
AV05-3/2CC-VT00-024VDC-LOC
electric Double-acting Base plate principle multiple - NC/NC - - Notched 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103007 2x3/2-way valve Series AV05 R422103007
AV05-3/2CC-VT00-024VDC-NLC
electric Double-acting Base plate principle multiple - NC/NC - - Not latching 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103080 2x3/2-way valve Series AV05 R422103080
AV05-3/2CC-VT00-024VDC-NO
electric Double-acting Base plate principle multiple - NC/NC - - without 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103008 2x3/2-way valve Series AV05 R422103008
AV05-3/2OO-VT00-024VDC-LOC
electric Double-acting Base plate principle multiple - NO/NO - - Notched 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 600 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103009 2x3/2-way valve Series AV05 R422103009
AV05-3/2OO-VT00-024VDC-NLC
electric Double-acting Base plate principle multiple - NO/NO - - Not latching 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 600 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103081 2x3/2-way valve Series AV05 R422103081
AV05-3/2OO-VT00-024VDC-NO
electric Double-acting Base plate principle multiple - NO/NO - - without 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 600 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103010 2x3/2-way valve Series AV05 R422103010
AV05-3/2CO-VT00-024VDC-LOC
electric Double-acting Base plate principle multiple - NC/NO - - Notched 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103011 2x3/2-way valve Series AV05 R422103011
AV05-3/2CO-VT00-024VDC-NLC
electric Double-acting Base plate principle multiple - NC/NO - - Not latching 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103082 2x3/2-way valve Series AV05 R422103082
AV05-3/2CO-VT00-024VDC-NO
electric Double-acting Base plate principle multiple - NC/NO - - without 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 2x3/2 Plate connection Slide valve, without overlap -10% / +10% R422103000 5/2-way valve Series AV05 R422103000
AV05-5/2AS-VT00-024VDC-LOC
electric Single-sided actuated Base plate principle multiple - - - - Notched 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With spring/air spring return 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103001 5/2-way valve Series AV05 R422103001
AV05-5/2AS-VT00-024VDC-NLC
electric Single-sided actuated Base plate principle multiple - - - - Not latching 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With spring/air spring return 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103077 5/2-way valve Series AV05 R422103077
AV05-5/2AS-VT00-024VDC-NO
electric Single-sided actuated Base plate principle multiple - - - - without 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With spring/air spring return 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103012 5/2-way valve Series AV05 R422103012
AV05-5/2AR-VT00-024VDC-LOC.
electric Single-sided actuated Base plate principle multiple - - - - Notched 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With air spring return 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103013 5/2-way valve Series AV05 R422103013
AV05-5/2AR-VT00-024VDC-NLC.
electric Single-sided actuated Base plate principle multiple - - - - Not latching 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With air spring return 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103083 5/2-way valve Series AV05 R422103083
AV05-5/2AR-VT00-024VDC-NO.
electric Single-sided actuated Base plate principle multiple - - - - without 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External With air spring return 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103002 5/2-way valve Series AV05 R422103002
AV05-5/2DS-VT00-024VDC-LOC
electric Double-acting Base plate principle multiple With collected venting of the control air - - - Notched 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103003 5/2-way valve Series AV05 R422103003
AV05-5/2DS-VT00-024VDC-NLC
electric Double-acting Base plate principle multiple With collected venting of the control air - - - Not latching 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103078 5/2-way valve Series AV05 R422103078
AV05-5/2DS-VT00-024VDC-NO
electric Double-acting Base plate principle multiple With collected venting of the control air - - - without 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 700 l/min soft sealing 5/2 Plate connection Slide valve, without overlap -10% / +10% R422103004 5/3-way valve Series AV05 R422103004
AV05-5/3CC-VT00-024VDC-LOC
electric Double-acting Base plate principle multiple - Closed center position - - Notched 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 5/3 Plate connection Slide valve, without overlap -10% / +10% R422103005 5/3-way valve Series AV05 R422103005
AV05-5/3CC-VT00-024VDC-NLC
electric Double-acting Base plate principle multiple - Closed center position - - Not latching 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 5/3 Plate connection Slide valve, without overlap -10% / +10% R422103079 5/3-way valve Series AV05 R422103079
AV05-5/3CC-VT00-024VDC-NO
electric Double-acting Base plate principle multiple With collected venting of the control air - - - without 40 µm 60 °C 8 bar 60 °C 5 mg/m³ 10 bar Compressed air -10 °C -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 5/3 Plate connection Slide valve, without overlap -10% / +10% R422103320 5/3-way valve Series AV05 R422103320
AV05-5/3EC-VT00-024VDC-NLC
electric Double-acting Base plate principle multiple With collected venting of the control air - 0.37 Ventilated center position Not latching 40 µm 60 °C, -10 °C 8 bar - 5 mg/m³ 10 bar Compressed air - -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 5/3, vented center position Plate connection Slide valve, without overlap -10% / +10% R422103321 5/3-way valve Series AV05 R422103321
AV05-5/3EC-VT00-024VDC-LOC
electric Double-acting Base plate principle multiple With collected venting of the control air - 0.37 Ventilated center position Notched 40 µm 60 °C, -10 °C 8 bar - 5 mg/m³ 10 bar Compressed air - -10 °C 3 bar 0 mg/m³ -0.9 bar 24 V External - 650 l/min soft sealing 5/3, vented center position Plate connection Slide valve, without overlap -10% / +10%