R901463130 Prop-Wegeventil
4WRLD16V150L-4X/MXY/24ND6U
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.62 R901464697 Prop-Wegeventil
4WRLD16V250L-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 11.86 R901471403 Prop-Wegeventil
4WRLD27E600LJ-4X/MXT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1850 27 4 3 270 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 600 NBR 24 V DC 20.78 R901471735 Prop-Wegeventil
4WRLD35E1000LJ-4X/MXT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-10-09-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 4700 35 4 3 350 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 1500 NBR 24 V DC 79 R901472450 Prop-Wegeventil
4WRLD16Q3-200M-4X/MXY/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol Q3 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.66 R901473284 Prop-Wegeventil
4WRLD16V1-250L-4X/MXY/24TD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherCAT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.62 R901474469 Prop-Wegeventil
4WRLD25E350SJ-4X/MPY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 280 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.58 R901476819 Prop-Wegeventil
4WRLD35V1000L-4X/MPT/24TD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-10-09-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherCAT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 4700 35 4 3 280 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 1500 NBR 24 V DC 70 R901486353 Prop-Wegeventil
4WRLD10V1-60L-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 280 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.44 R901488644 Prop-Wegeventil
4WRLD16E250LJ-4X/MXT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.6 R901489761 Prop-Wegeventil
4WRLD10V100L-4X/MXY/24SD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, Sercos III Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.08 R901490678 Prop-Wegeventil
4WRLD16V200M-4X/MPT/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 11.86 R901491897 Prop-Wegeventil
4WRLD10V1-100L-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 280 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.12 R901491907 Prop-Wegeventil
4WRLD10V100L-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9 R901491916 Prop-Wegeventil
4WRLD16V1-150L-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 11.9 R901491919 Prop-Wegeventil
4WRLD16V150L-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 11.9 R901491921 Prop-Wegeventil
4WRLD16V250L-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.66 R901491924 Prop-Wegeventil
4WRLD16V200M-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.48 R901491981 Prop-Wegeventil
4WRLD25V400L-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 280 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.58 R901492706 Prop-Wegeventil
4WRLD16V1-250P-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.64 R901495582 Prop-Wegeventil
4WRLD10V100L-4X/MPT/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 280 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.08 R901497635 Prop-Wegeventil
4WRLD16V1-250L-4X/MPT/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.6 R901502973 Prop-Wegeventil
4WRLD25V1-400L-4X/MXY/24TD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherCAT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 19.64 R901529312 Prop-Wegeventil
4WRLD27E600LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1850 27 4 3 270 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 600 NBR 24 V DC 21 R901532918 Prop-Wegeventil
4WRLD25W8-350LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol W8 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.58 R901534147 Prop-Wegeventil
4WRLD25V400L-4X/MXT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.58 R901537529 Prop-Wegeventil
4WRLD10V100L-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 280 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.88 R901537962 Prop-Wegeventil
4WRLD10V100L-4X/MXT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.08 R901537990 Prop-Wegeventil
4WRLD16E250LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.6 R901537991 Prop-Wegeventil
4WRLD25E400LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.58 R901539104 Prop-Wegeventil
4WRLD16V1-250L-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 7.5 R901540928 Prop-Wegeventil
4WRLD16W6-200LJ-4X/MXY/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol W6 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 10 R901541003 Prop-Wegeventil
4WRLD25V1-400L-4X/MXY/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 19.5 R901543463 Prop-Wegeventil
4WRLD10V1-100L-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 350 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.08 R901544466 Prop-Wegeventil
4WRLD27W8-430LJ-4X/MPT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1850 27 4 3 270 Symbol W8 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 600 NBR 24 V DC 20.78 R901546311 Prop-Wegeventil
4WRLD16V150L-4X/MXY/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12 R901546411 Prop-Wegeventil
4WRLD10W6-100LJ-4X/MXY/24TD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherCAT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 350 Symbol W6 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.8 R901546412 Prop-Wegeventil
4WRLD16W6-200LJ-4X/MXY/24TD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherCAT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol W6 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.66 R901547557 Prop-Wegeventil
4WRLD27W8-430LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1850 27 4 3 270 Symbol W8 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 600 NBR 24 V DC 20.78 R901547925 Prop-Wegeventil
4WRLD35W6-1200LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-10-09-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 4700 35 4 3 350 Symbol W6 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 1500 NBR 24 V DC 97 R901548254 Prop-Wegeventil
4WRLD16V150L-4X/MPT/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 280 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 11.86 R901548637 Prop-Wegeventil
4WRLD10V100P-4X/VXY/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRLD 100 FKM 24 V DC 9.1 R901550110 Prop-Wegeventil
4WRLD25V400L-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol V HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.9 R901550464 Prop-Wegeventil
4WRLD16W8-200LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol W8 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 11.86 R901552606 Prop-Wegeventil
4WRLD10E1-100LJ-4X/MPT/24TD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherCAT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 280 Symbol E1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.08 R901561401 Prop-Wegeventil
4WRLD25E1-400LJ-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol E1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.5 R901566378 Prop-Wegeventil
4WRLD25W8-350LJ-4X/MXT/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol W8 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 19.72 R901567531 Prop-Wegeventil
4WRLD10E1-60LJ-4X/MPT/24TD6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-05-05-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherCAT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 300 10 4 3 280 Symbol E1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 100 NBR 24 V DC 9.1 R901569538 Prop-Wegeventil
4WRLD25V1-400P-4X/MXY/24ND6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-08-08-0-05 Plate construction Analog, setpoint ±10 V, Analog, setpoint 4 … 20 mA, Digital, PROFINET RT Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 1250 25 4 3 350 Symbol V1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 400 NBR 24 V DC 18.9 R901572273 Prop-Wegeventil
4WRLD16E250LJ-4X/MXY/24ED6T
Electric with integrated digital axle controller Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU<br>RoHS - Directive 2011/65/EU ISO 4401-07-07-0-05 Plate construction Analog, Setpoint ±10 V, Analog, Setpoint 4 … 20 mA, Digital, EtherNET/IP Device connector 12-pin (11 + PE) according to EN 175201-804 Device connector 12-pin (11 + PE) 800 16 4 3 350 Symbol E HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRLD 250 NBR 24 V DC 12.68