| Aventics R412026834 | Flow sensor Series AF2 IO-Link AF2-AS2-FLX-G038 | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 3/8 | OLED | - | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5 l/min | 0 bar | 17 V DC | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), with mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | AS2 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412027176 | Flow sensor Series AF2 IO-Link AF2-AS2-FLX-G038-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 3/8 | OLED | - | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5 l/min | 0 bar | 17 V DC | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | AS2 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412026835 | Flow sensor Series AF2 IO-Link AF2-AS3-FLX-G012 | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | - | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 2445 l/min | 1630 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | 17 V DC | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), with mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | AS3 | Flow measuring principle: calorimetric | °C, °F | - |
| R412027177 | Flow sensor Series AF2 IO-Link AF2-AS3-FLX-G012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | - | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 2445 l/min | 1630 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | 17 V DC | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | AS3 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412027180 | Flow sensor Series AF2 Ethernet AF2-AS3-ETH-G012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | - | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 2445 l/min | 1630 l/min | 16 bar | 5 W | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | AS3 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412026839 | Flow sensor Series AF2 Ethernet AF2-AS5-ETH-G100 | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1 | OLED | - | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 6490 l/min | 4326 l/min | 16 bar | 5 W | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4326 l/min | 22 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, with mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | AS5 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412027178 | Flow sensor Series AF2 Ethernet AF2-AS5-FLX-G100-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1 | OLED | - | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 6490 l/min | 4326 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4326 l/min | 22 l/min | 0 bar | 17 V DC | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | AS5 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412026837 | Flow sensor Series AF2 Ethernet AF2-AS2-ETH-G038 | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 3/8 | OLED | - | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | 5 W | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, with mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | AS2 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412027179 | Flow sensor Series AF2 Ethernet AF2-AS2-ETH-G038-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 3/8 | OLED | - | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | 5 W | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | AS2 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412026838 | Flow sensor Series AF2 Ethernet AF2-AS3-ETH-G012 | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | - | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 2445 l/min | 1630 l/min | 16 bar | 5 W | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, with mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | AS3 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412026836 | Flow sensor Series AF2 IO-Link AF2-AS5-FLX-G100 | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1 | OLED | - | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 6490 l/min | 4326 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4326 l/min | 22 l/min | 0 bar | 17 V DC | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), with mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | AS5 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics R412027181 | Flow sensor Series AF2 Ethernet AF2-AS5-ETH-G100-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1 | OLED | - | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 6490 l/min | 4326 l/min | 16 bar | 5 W | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4326 l/min | 22 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | AS5 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics 8652AVBP4JA001N | Flow sensor Series AF2 Ethernet AF2-652-ETH-N012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1/2 NPT | OLED | X-coded | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 2445 l/min | 1630 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | 652 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics G652AV004JA0010 | Flow sensor Series AF2 Ethernet AF2-652-ETH-R012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5.3 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | DN15 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics G653AV006JA0000 | Flow sensor Series AF2 IO-Link AF2-653-FLX-G100-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1 | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 4417 l/min | 2945 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 2945 l/min | 14.7 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN25 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics G653AV006JA0010 | Flow sensor Series AF2 Ethernet AF2-653-ETH-G100-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1 | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 4417 l/min | 2945 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 2945 l/min | 14.7 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | TCP/IP, OPC UA, MQTT | DN25 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics G652AVBP4JA001N | Flow sensor Series AF2 Ethernet AF2-652-ETH-G012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | X-coded | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 2445 l/min | 1630 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | 652 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics 8652AVBP4JA000N | Flow sensor Series AF2 IO-Link AF2-652-FLX-N012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1/2 NPT | OLED | A-coded | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 2445 l/min | 1630 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | 652 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics 8653AV006JA0000 | Flow sensor Series AF2 IO-Link AF2-653-FLX-N100-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1 NPT | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 4417 l/min | 2945 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 2945 l/min | 14.7 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN25 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics G652AVBP4JA000N | Flow sensor Series AF2 IO-Link AF2-652-FLX-G012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | A-coded | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 2445 l/min | 1630 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1630 l/min | 8 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | 652 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics 8652AV004JA0010 | Flow sensor Series AF2 Ethernet AF2-652-ETH-N012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1/2 NPT | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5.3 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | DN15 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics 8653AV006JA0010 | Flow sensor Series AF2 Ethernet AF2-653-ETH-N100-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1 NPT | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 4417 l/min | 2945 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 2945 l/min | 14.7 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | TCP/IP, OPC UA, MQTT | DN25 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics G653AVBP6JA001N | Flow sensor Series AF2 Ethernet AF2-653-ETH-G100-CON | CE declaration of conformity, RoHS | G 1 | OLED | X-coded | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 6490 l/min | 4328 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4328 l/min | 22 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | TCP/IP, OPC UA, MQTT | 653 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics 8653AVBP6JA001N | Flow sensor Series AF2 Ethernet AF2-653-ETH-N100-CON | CE declaration of conformity, RoHS | 1 NPT | OLED | X-coded | 8-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 6490 l/min | 4328 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4328 l/min | 22 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | TCP/IP, OPC UA, MQTT | 653 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics G653AVBP6JA000N | Flow sensor Series AF2 IO-Link AF2-653-FLX-G100-CON | CE declaration of conformity, RoHS | G 1 | OLED | A-coded | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 6490 l/min | 4328 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4328 l/min | 22 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP/NPN/push-pull, switchable | bar, psi | IO-Link | 653 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics 8653AVBP6JA000N | Flow sensor Series AF2 IO-Link AF2-653-FLX-N100-CON | CE declaration of conformity, RoHS | 1 NPT | OLED | A-coded | 5-pole | M12x1 | Plug | 5 µm | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 50 °C | 6490 l/min | 4328 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 4328 l/min | 22 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP/NPN/push-pull, switchable | bar, psi | IO-Link | 653 | Flow measuring principle: calorimetric | °C, °F | - |
| Aventics G652AV004JA0000 | Flow sensor Series AF2 IO-Link AF2-652-FLX-G012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | G 1/2 | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5.3 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN15 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics 8652AV004JA0000 | Flow sensor Series AF2 IO-Link AF2-652-FLX-N012-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1/2 NPT | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 1590 l/min | 1060 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 1060 l/min | 5.3 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN15 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028643 | Flow sensor Series AF2 Ethernet AF2-HF-ETH-R112-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | R 1 1/2 | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 11300 l/min | 7540 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 7540 l/min | 38 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | DN40 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028645 | Flow sensor Series AF2 Ethernet AF2-HF-ETH-N112-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1 1/2 NPT | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 11300 l/min | 7540 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 7540 l/min | 38 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | DN40 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028647 | Flow sensor Series AF2 Ethernet AF2-HF-ETH-R200-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | R 2 | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 17600 l/min | 11780 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 11780 l/min | 59 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | DN50 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028649 | Flow sensor Series AF2 Ethernet AF2-HF-ETH-N200-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | R 2 NPT | OLED | X-coded | 8-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 17600 l/min | 11780 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 11780 l/min | 59 l/min | 0 bar | - | Integrated web server, 48 VDC connection via Power over Ethernet, without mounting | OPC UA, MQTT, integrated web server | bar, psi | Ethernet, TCP/IP, OPC UA, MQTT | DN50 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028642 | Flow sensor Series AF2 IO-Link AF2-HF-FLX-R112-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | R 1 1/2 | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 11300 l/min | 7540 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 7540 l/min | 38 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN40 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028644 | Flow sensor Series AF2 IO-Link AF2-HF-FLX-N112-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | 1 1/2 NPT | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 11300 l/min | 7540 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 7540 l/min | 38 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN40 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028646 | Flow sensor Series AF2 IO-Link AF2-HF-FLX-R200-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | R 2 | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 17600 l/min | 11780 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 11780 l/min | 59 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN50 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |
| Aventics R412028648 | Flow sensor Series AF2 IO-Link AF2-HF-FLX-N200-CON | CE declaration of conformity, RoHS, UL (Underwriters Laboratories) | R 2 NPT | OLED | A-coded | 5-pole | M12x1 | Plug | - | l/s, l/min, m³/min, m³/h, ft³/s, ft³/min | 60 °C | 17600 l/min | 11780 l/min | 16 bar | - | Compressed air, argon, nitrogen, carbon dioxide | -20 °C | 11780 l/min | 59 l/min | 0 bar | - | Output signal: 1 analogue output 4 mA ... 20 mA + 1 digital/analogue output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable) + 1 digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud), without mounting | PNP, NPN, push-pull, 1 x IO-Link | bar, psi | IO-Link, analogue | DN50 | Flow measuring principle: calorimetric | °C, °F | Stainless steel 1.4301 |