Festo ControllerManufacturer type key:

Price & Availability

Availability:
Shipping Area:
entire EU·No minimum order value|

Found it cheaper elsewhere? Send us the offer as a link or PDF, we usually match it.

Packaging Unit:
1 piece
We accept
Invoice
Prepayment
Visa
Mastercard
American Express
PayPal
Eps
Ideal
Przelewy24
We also supplyView range

Fittings & hoses

Threaded fittings, couplings, valves and hoses in brass, stainless steel and plastic.

Support

Advice on selection, alternatives and availability

Partbase Support, SupportFranz Bewerunge, SupportOle Dening, Support
Mon - Fri from 8:00 AM - 6:00 PM
+49 39203 863988 (German & English)sales@partbase.com (all languages)
Featured in
  • konstruktionspraxis
  • O+P Fluidtechnik
  • e-commerce magazin
  • Industrieanzeiger
Also via
  • Conrad Marketplace
  • SAP Ariba
  • Simple System

Features for 5226780 from Festo

Dimensions W x L x H
42,2 mm x 76,5 mm x 125,8 mm
Grid dimension
18.9 mm
Mounting type
with mounting rail
Max. number of modules
10
Mounting position
verticalhorizontal
Ambient temperature
-5 °C ... 50 °C
Note on ambient temperature
-5 - 60 °C with vertical installation
Storage temperature
-20 °C ... 70 °C
Relative humidity
95 %non-condensing
Degree of protection
IP20
Corrosion resistance class CRC
0 - no corrosion stress
Vibration resistance
Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistance
Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection against direct and indirect contact
PELV
LABS conformity
VDMA24364 zone III
CE mark (see declaration of conformity)
to EU EMC Directiveto EU RoHS Directive
UKCA mark (see declaration of conformity)
to UK EMC regulationsto UK RoHS regulations
KC mark
KC-EMV
Approval
RCM markc UL us - Listed (OL)
Certificate issuing body
UL E239998
Materials note
RoHS-compliant
Housing material
PA
Diagnostics via LED
Force modeModule statusNetwork status engineering port 1Network status EtherCATRunVoltage supply electronics/sensorsLoad voltage supplySystem fault
Operating elements
DIP switch for RUN/STOP
IP address setting
DHCPvia CODESYS
Fieldbus interface, type
Ethernet
Fieldbus interface, protocol
EtherCATEtherCAT CoEEtherCAT EoEEtherCAT FoEEtherCAT Master
Fieldbus interface, function
Bus connection outgoing
Fieldbus interface, connection type
Socket
Fieldbus interface, connection technology
RJ45
Fieldbus interface, connection pattern
00995789
Fieldbus interface, number of pins/wires
8
Fieldbus interface, galvanic isolation
ja
Fieldbus interface, transmission rate
100 Mbit/s
Ethernet interface, connection type
Socket
Ethernet interface, protocol
EasyIPModbus TCPOPC-UATCP/IP
Ethernet interface, function
Diagnostics
Ethernet interface, connection technology
RJ45
Ethernet interface, connection pattern
00995789
Ethernet interface, number of pins/wires
8
Ethernet interface, transmission speed
10 Mbit/s100 Mbit/s
Maximum address volume of inputs
64 bytes
Maximum address volume of outputs
64 bytes
System parameters
Diagnostic memoryFail-safe reactionSystem start
Module parameters
Channel alarms undervoltageProcess value representation analogue modules
Configuration support
CODESYS V3
Additional functions
CODESYS V3
CPU data
Dual core 650 MHz
Power supply, function
Electronics and sensors
Power supply, connection type
Terminal strip
Power supply, note on connection type
> 4 A and UL, 2x terminal strip for voltage supply
Power supply, connection technology
Spring-loaded terminal
Power supply, connection pattern
00995847
Power supply, number of pins/wires
4
Nominal operating voltage DC for electronics/sensors
24 V
Permissible voltage fluctuations of electronics/sensors
± 25 %
Power supply, conductor cross section
0.2 mm² ... 1.5 mm²
Power supply, note on conductor cross section
0.2 - 2.5 mm² for flexible conductor without wire end ferrule
Max. power supply
8 A
Intrinsic current consumption at nominal operating voltage of electronics/sensors
typically 65 mA
Mains failure bridging
20 ms
Reverse polarity protection
24 V sensor supply against 0 V sensor supply
Programming software
CODESYS provided by Festo
Program memory
12 MB user program
Processing time
approx. 200 µs/1 k instructions
Function blocks
and othersRead CPX-E module diagnosticsCPX-E diagnostic statusCopy CPX-E diagnostic trace
Buffer time of real-time clock
3 weeks
Flags
Variable concept CODESYS
Documents

Further information for 5226780 from Festo

Article authenticity
Original article
Article condition
New
Single weight
145 g
Dimensions (L x W x H)
not available
Country of origin**
On request
Customs goods number
85371091
GTIN
4052568421458
RoHS compliant
Yes
Manufacturer
Festo

Support

Support Mitarbeiter

How can we help?

Get in touch with our support team

Opening hours
Mon - Fri from 8:00 AM - 6:00 PM
sales@partbase.com
+49 39203 863988

Payment Methods

Invoice
Prepayment
Visa
Mastercard
American Express
PayPal
Eps
Ideal
Przelewy24

Our Advantages

Top Prices
High Availability
Large Portfolio
Flexible Payment Methods