R901372986 Prop-Wegeventil
4WRPEH6C3B24L-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 24 FKM 24 V DC 2.98 R901376972 Prop-Wegeventil
4WRPEH6C3B24L-3X/V/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 24 FKM 24 V DC 3 R901381804 Prop-Wegeventil
4WRPEH6CB24L-3X/M/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 24 NBR 24 V DC 2.86 R901408241 Prop-Wegeventil
4WRPEH6C5B24L-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 24 FKM 24 V DC 3 R901412522 Prop-Wegeventil
4WRPEH6C4B12L-3X/M/24A1-561
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 12 NBR 24 V DC 3 R901422942 Prop-Wegeventil
4WRPEH6CB40L-3X/V/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 40 FKM 24 V DC 3 R901423624 Prop-Wegeventil
4WRPEH6C1B24L-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C1 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 24 FKM 24 V DC 3.12 R901429091 Prop-Wegeventil
4WRPEH6CB15P-3X/M/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 30 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 15 NBR 24 V DC 3 R901431666 Prop-Wegeventil
4WRPEH6C4B12L-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 12 FKM 24 V DC 3 R901436252 Prop-Wegeventil
4WRPEH6C1B12L-3X/M/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 12 NBR 24 V DC 2.98 R901438744 Prop-Wegeventil
4WRPEH6CB40L-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 40 FKM 24 V DC 3 R901442988 Prop-Wegeventil
4WRPEH6C3B40L-3X/M/24F1-15
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3.12 R901445011 Prop-Wegeventil
4WRPEH6C1B04L-3X/M/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 8 6 4 4 350 Symbol C1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 4 NBR 24 V DC 3 R901447941 Prop-Wegeventil
4WRPEH6C1B04L-3X/M/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 8 6 4 4 350 Symbol C1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 4 NBR 24 V DC 2.99 R901449344 Prop-Wegeventil
4WRPEH6C5B24L-3X/V/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 24 FKM 24 V DC 3.1 R901450160 Prop-Wegeventil
4WRPEH6C5B40P-3X/V/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 40 FKM 24 V DC 3.12 R901455671 Prop-Wegeventil
4WRPEH6CB12L-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 12 FKM 24 V DC 3.14 R901457197 Prop-Wegeventil
4WRPEH6C4B12L-3X/V/24F1-967
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 12 FKM 24 V DC 3.12 R901462154 Prop-Wegeventil
4WRPEH6CB24L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 50 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 24 NBR 24 V DC 3 R901462156 Prop-Wegeventil
4WRPEH6C3B04L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 8 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 4 NBR 24 V DC 3 R901462158 Prop-Wegeventil
4WRPEH6C4B12L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 22 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 12 NBR 24 V DC 3.2 R901464454 Prop-Wegeventil
4WRPEH6C3B02L-3X/V/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 7 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 2 FKM 24 V DC 3.12 R901467112 Prop-Wegeventil
4WRPEH6C4B40L-3X/M/D24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3.28 R901468200 Prop-Wegeventil
4WRPEH6C3B25P-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 41 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 25 FKM 24 V DC 3 R901477187 Prop-Wegeventil
4WRPEH6C1B40P-3X/V/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C1 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 40 FKM 24 V DC 3.12 R901477205 Prop-Wegeventil
4WRPEH6CB04L-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 8 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 4 FKM 24 V DC 3.12 R901478153 Prop-Wegeventil
4WRPEH6C3B12L-3X/M/24A1-A28
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 12 NBR 24 V DC 3 R901478981 Prop-Wegeventil
4WRPEH6C4B40L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 50 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3 R901478983 Prop-Wegeventil
4WRPEH6CB12L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 22 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 12 NBR 24 V DC 2.96 R901487525 Prop-Wegeventil
4WRPEH6C3B40L-3X/M/24A1-967
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3.12 R901490377 Prop-Wegeventil
4WRPEH6C3B24L-3X/V/24C6
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint ±10 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 24 FKM 24 V DC 2.92 R901490877 Prop-Wegeventil
4WRPEH6C1B40L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 50 6 4 4 350 Symbol C1 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3 R901491482 Prop-Wegeventil
4WRPEH6CB04P-3X/M/24A1-561
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 8 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 4 NBR 24 V DC 2.98 R901491483 Prop-Wegeventil
4WRPEH6CB04P-3X/M/24A1-303
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 8 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 4 NBR 24 V DC 3 R901492707 Prop-Wegeventil
4WRPEH6C5B04L-3X/M/24A1-303
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 8 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 4 NBR 24 V DC 3.14 R901492708 Prop-Wegeventil
4WRPEH6C5B04L-3X/M/24A1-561
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 8 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 4 NBR 24 V DC 3.14 R901497634 Prop-Wegeventil
4WRPEH6C4B15P-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 30 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 15 NBR 24 V DC 3.2 R901497949 Prop-Wegeventil
4WRPEH6C3B12L-3X/M/D24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C3 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 12 NBR 24 V DC 3.27 R901499904 Prop-Wegeventil
4WRPEH6C5B40P-3X/M/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3.12 R901502058 Prop-Wegeventil
4WRPEH6C4B24L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 50 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 24 NBR 24 V DC 2.2 R901504930 Prop-Wegeventil
4WRPEH6C4B15P-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 30 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 15 FKM 24 V DC 2.98 R901528618 Prop-Wegeventil
4WRPEH6C5B40P-3X/V/D24F1-967
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 40 FKM 24 V DC 3.32 R901528879 Prop-Wegeventil
4WRPEH6CB15P-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 30 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 15 FKM 24 V DC 3.12 R901528882 Prop-Wegeventil
4WRPEH6CB25P-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 41 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 25 FKM 24 V DC 3.1 R901532165 Prop-Wegeventil
4WRPEH6CB40P-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 50 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3.11 R901533429 Prop-Wegeventil
4WRPEH6C4B12L-3X/V/24F1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint 4 … 20 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 22 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 12 FKM 24 V DC 3 R901536131 Prop-Wegeventil
4WRPEH6C5B40L-3X/M/24L1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction IO-Link 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 5-pin, M12 x 1, coding A 50 6 4 4 350 Symbol C5 HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3.13 R901537367 Prop-Wegeventil
4WRPEH6CB40L-3X/M/24C6
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint ±10 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 40 NBR 24 V DC 3 R901537369 Prop-Wegeventil
4WRPEH6CB24L-3X/M/24C6
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Analog, setpoint ±10 mA 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) - 6 4 4 350 Symbol C HL, HLP, HLPD, HVLP, HVLPD, HFC 4WRPEH6 24 NBR 24 V DC 3 R901539189 Prop-Wegeventil
4WRPEH6C4B40P-3X/V/24A1
Electrical with integrated electronics Industrial hydraulics CE - Electromagnetic Compatibility 2014/30/EU; RoHS - Directive 2011/65/EU ISO 4401-03-02-0-05 Plate construction Setpoint input ±10 V 3-pole device plug (2 + PE) according to EN 175301-803 Device connector 7-pin (6 + PE) 50 6 4 4 350 Symbol C4 HL, HLP, HLPD, HVLP, HVLPD, HETG, HEES, HEPG, HFDU, HFDR 4WRPEH6 40 FKM 24 V DC 2